log

age author description
Mon, 12 Sep 2016 22:36:23 +0100 Rod Selfridge HarpD2 - minor edits
Tue, 23 Aug 2016 21:15:35 +0100 Rod Selfridge Control added that reduces gain to 0 if Reynolds number < 40. No vortices shed below this number
Tue, 23 Aug 2016 05:45:54 +0100 Rod Selfridge Small error on difference frequency rectified.
Tue, 16 Aug 2016 09:01:42 +0100 Rod Selfridge Increased line time for harmonic number change
Wed, 10 Aug 2016 08:16:29 +0100 Rod Selfridge Adding in lock in control to V
Tue, 09 Aug 2016 20:47:58 +0100 Rod Selfridge Experimenting changing the values of V to match the average. Disguarded as no evidence this is what happens in nature.
Wed, 27 Jul 2016 22:12:18 +0100 Rod Selfridge Corrections to model and have adjusted the objects so that the workflow made more sense / easier to understand.
Mon, 25 Jul 2016 20:04:24 +0100 Rod Selfridge Difference frequency sorted to remain constant during lock in.