Mercurial > hg > sonic-visualiser
annotate deploy/win64/build-and-package.bat @ 1886:d93e0826b098 appimage
Ah, I see. Well, presumably this still saves writing the name twice
author | Chris Cannam |
---|---|
date | Wed, 27 Jun 2018 13:51:33 +0100 |
parents | 9f26f92bf89f |
children | a594146c1ed8 |
rev | line source |
---|---|
Chris@1839 | 1 rem Run this from within the top-level SV dir: deploy\win64\build-and-package.bat |
Chris@1827 | 2 |
Chris@1827 | 3 set STARTPWD=%CD% |
Chris@1827 | 4 |
Chris@1827 | 5 if not exist "C:\Program Files (x86)\SMLNJ\bin" ( |
Chris@1827 | 6 @ echo Could not find SML/NJ, required for Repoint |
Chris@1841 | 7 @ exit /b 2 |
Chris@1827 | 8 ) |
Chris@1827 | 9 |
Chris@1827 | 10 if not exist "C:\Program Files (x86)\WiX Toolset v3.11\bin" ( |
Chris@1827 | 11 @ echo Could not find WiX Toolset |
Chris@1841 | 12 @ exit /b 2 |
Chris@1827 | 13 ) |
Chris@1827 | 14 |
Chris@1839 | 15 @echo Rebuilding 32-bit |
Chris@1827 | 16 |
Chris@1827 | 17 cd %STARTPWD% |
Chris@1841 | 18 del /q /s build_win32 |
Chris@1839 | 19 call .\deploy\win64\build-32.bat |
Chris@1839 | 20 if %errorlevel% neq 0 exit /b %errorlevel% |
Chris@1827 | 21 |
Chris@1839 | 22 @echo Rebuilding 64-bit |
Chris@1827 | 23 |
Chris@1839 | 24 cd %STARTPWD% |
Chris@1841 | 25 del /q /s build_win64 |
Chris@1839 | 26 call .\deploy\win64\build-64.bat |
Chris@1839 | 27 if %errorlevel% neq 0 exit /b %errorlevel% |
Chris@1827 | 28 |
Chris@1839 | 29 set PATH=%PATH%;"C:\Program Files (x86)\WiX Toolset v3.11\bin" |
Chris@1827 | 30 |
Chris@1839 | 31 @echo Packaging 32-bit |
Chris@1827 | 32 |
Chris@1839 | 33 cd %STARTPWD%\build_win32 |
Chris@1827 | 34 del sonic-visualiser.msi |
Chris@1827 | 35 candle -v ..\deploy\win32\sonic-visualiser.wxs |
Chris@1827 | 36 light -b . -ext WixUIExtension -ext WixUtilExtension -v sonic-visualiser.wixobj |
Chris@1839 | 37 if %errorlevel% neq 0 exit /b %errorlevel% |
Chris@1827 | 38 del sonic-visualiser.wixobj |
Chris@1827 | 39 del sonic-visualiser.wixpdb |
Chris@1827 | 40 |
Chris@1839 | 41 @echo Packaging 64-bit |
Chris@1827 | 42 |
Chris@1839 | 43 cd %STARTPWD%\build_win64 |
Chris@1827 | 44 del sonic-visualiser.msi |
Chris@1827 | 45 candle -v ..\deploy\win64\sonic-visualiser.wxs |
Chris@1827 | 46 light -b . -ext WixUIExtension -ext WixUtilExtension -v sonic-visualiser.wixobj |
Chris@1839 | 47 if %errorlevel% neq 0 exit /b %errorlevel% |
Chris@1827 | 48 del sonic-visualiser.wixobj |
Chris@1827 | 49 del sonic-visualiser.wixpdb |
Chris@1839 | 50 |
Chris@1839 | 51 @echo Done |
Chris@1839 | 52 |